BHB-Glo™ (Ketone Body) Assay
Efficient Detection of BHB in Diverse Samples
The BHB-Glo™ (Ketone Body) Assay is a fast and sensitive method for detecting β-hydroxybutyrate (BHB) from various biological samples, such as cultured cells, media, tissue homogenates and serum. Based on bioluminescent technology, the BHB-Glo™ Assay can detect subtle changes in ketosis as well as ketone body consumption and secretion. Its streamlined sample preparation protocol involves acid treatment and neutralization directly in the assay wells, eliminating the need for cell collection, centrifugation, spin columns and deproteinization. The assay is adaptable to a 384-well format, facilitating quick analysis of many samples.
How the BHB-Glo™ Assay Works
β-Hydroxybutyrate (BHB) Dehydrogenase catalyzes the oxidation of BHB, simultaneously reducing NAD+ to NADH. In the presence of NADH, Reductase converts the proluciferin Reductase Substrate into luciferin. This reaction is detected by Ultra-Glo™ Recombinant Luciferase, which emits light proportionate to the amount of BHB in the sample.
Simple Add-and-Read Protocol Saves Time
Accurately Detect the Smallest Changes in BHB
|
Sensitivity (S/B >5) |
800nM |
|
|
Limit of Detection (S/N >3) |
50nM |
|
|
Linear Range |
50nM to 25μM |
|
|
Maximum Assay Window (S/B) |
>200 |
|
Measure BHB Secretion from Hepatocytes
The BHB-Glo™ Assay can be used to monitor intracellular and extracellular BHB levels in cell culture. In the data shown, HepG2 cells were plated in a 96-well plate, and then media samples were removed at prescribed time points to monitor BHB secretion over time. Extracellular BHB was measured using the BHB-Glo™ Assay. Greater than sixfold signal above background was observed at 24 hours.
Do you want to learn more about our cellular energy metabolism tools and the innovative technology that powers these assays?
Protocols
Complete Protocol
Specifications
Catalog Number:
What's in the box?
| Item | Part # | Size | Concentration |
|---|---|---|---|
β-Hydroxybutyrate Dehydrogenase |
J414A | 1 × 100μl | |
β-Hydroxybutyrate, 10mM |
J415A | 1 × 50μl | |
Reductase |
G884A | 1 × 55μl | 6mg/ml |
Reductase Substrate |
G885A | 1 × 55μl | |
Luciferin Detection Solution |
J135A | 1 × 5ml | |
NAD |
J136B | 1 × 275μl | |
Neutralization Buffer |
J153A | 1 × 15ml | |
NADP+ |
J154B | 1 × 100μl | |
0.6N HCl |
J402A | 1 × 15ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.U.S. Pat. Nos. 9,273,343 and 9,951,372, European Pat. No. 2751089, Japanese Pat. No. 6067019 and other patents pending.
What's in the box?
| Item | Part # | Size | Concentration |
|---|---|---|---|
β-Hydroxybutyrate Dehydrogenase |
J414B | 1 × 1ml | |
β-Hydroxybutyrate, 10mM |
J415A | 1 × 50μl | |
Reductase |
G884B | 1 × 275μl | 6mg/ml |
Reductase Substrate |
G885B | 1 × 275μl | |
Luciferin Detection Solution |
J135B | 1 × 50ml | |
NAD |
J136C | 1 × 1ml | |
Neutralization Buffer |
J153A | 1 × 15ml | |
NADP+ |
J154C | 1 × 500μl | |
0.6N HCl |
J402A | 1 × 15ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.U.S. Pat. Nos. 9,273,343 and 9,951,372, European Pat. No. 2751089, Japanese Pat. No. 6067019 and other patents pending.
Resources
Related Products
Similar Products
Glucose-Glo™ Assay
Easily detect glucose from a variety of biological samples.
J6021, J6022
Pyruvate-Glo™ Assay
Fast and sensitive method for detecting pyruvate in various biological samples.
J4051, J4052
Triglyceride-Glo™ Assay
Detects triglyceride levels by measuring glycerol that is released from an enzymatic reaction with a lipase.
J3160, J3161
Metabolite-Glo™ Detection System
Bioluminescent NAD(P)H detection toolkit for metabolite detection in biological samples.
J9030, J9040
Frequently Used With
RealTime-Glo™ MT Cell Viability Assay
A bioluminescent method to kinetically monitor viability in cell culture up to 72 hours.
G9711, G9712, G9713
CellTiter-Fluor™ Cell Viability Assay
A non-lytic, fluorescent cell viability assay with multiplex capability.
G6080, G6081, G6082
CellTiter-Glo® 2.0 Cell Viability Assay
Updated CellTiter-Glo® Cell Viability Assay with improved reagent stability. Quantifies cell proliferation based on ATP detection.
G9241, G9242, G9243
GloMax® Discover System
High-performance microplate reader for detecting luminescence, fluorescence and absorbance.
GM3000